230v 3 Phase Motor On 208v. Webwill a 230v 3 phase motor run on 208v? Web208v is *not* the same as 240v. 480v is the voltage between phases.
Webthe transformer secondary is usually 480 (or 240 or 208) and the motors are rated 460, 230 or 200 volts. 480 and 460 are considered the same. Webcan you run a 230v single phase motor on 208v?

Regal Q3102 1HP 208V-230V/460V Three Phase Pool and Spa Motor | eBay
In this quick video Bryan talks How is 208 volts different than 230/240 volts. Read all the tech tips, take the quizzes and find our handy calculators at hvacrschool.com/. 230v 3 Phase Motor On 208v
Webat 208v this service factor capability, is gone, your service factor at 208 volts is 1. 0. Webcan you run 230v on 208v? Webthe actual information for this particular situation is a single phase 230v rated 3hp motor (lake fountain) is currently running on 208v from a 3 phase wye system. Webthe maximum current allowed is 5. 1 amps (or 10. 2 @ 2:1) i see this type of amp rating on 230/200 volt and 230/208 volt rated motors quite a bit, scotty.
Web2hp (1. 5kw) stainless steel motor, 3 phase, b3/ b5/ b14. Good price stainless steel motor with rated power 1. 5kw, rated voltage 208v~230v/ 460v, tefc cooling method, raged. Web3 phase motor specifications & testing parameters horsepower motor dia. Make & rpm volts phase hz service factor full load amps max load amps line to line.
GTR Brother BGFM15-040TE2C 3-Phase 40:1 Induction Motor 1/20 Hp 208V









Wiring 208/460 3 phase wye motor for low voltage. T1-T7, T2-T8, T3-T9, T4-T5-T6
I had a noisy condenser fan motor the customer wanted changed. The bearings were on the verge of locking up.
Explanation of how we derive 120/240 V and 120/208 V from various Transformer Secondaries. Additional video of interest: "120/240 V In-Phase or Out-of-Phase" youtu.be/nOSYHUxHxG8 PLEASE NOTE: The arrows above the left schematic show that this is one winding that has simply been tapped in the center. The waveforms below it in the lower left can give the wrong impression that the "halves" of the winding are out-of-phase with each other. This is because I'm using the neutral as a reference…
This video will show you how to wire up a 9 wire 3 phase motor to a 3 phase 240 volt system. Watch till the end for my Tech Tip. If performing on site, be sure to power off all incoming power before handling electrical circuits.
How is 208 volts different than 230/240 volts
Final Words
Webutilization low voltage range a. 108 187 216 249 432 540 630. Service entrance voltage high range b. 127 220 254 293 508 635 725.
230v 3 Phase Motor On 208v. Weba heater is a device that protects a motor from thermal overloads due to excess current in the windings. According to the nec, the overload rating must not exceed 115% of the full.